Swimming Pool Refinishing - Restoration and Resurfacing
AQUAGUARD 5001 Sealer/Primer
DATA INFORMATION

Description: AG 5001 is a 100% solids epoxy primer. Two-component system; Resin and Hardener. AquaGuard 5001 is a
very low viscosity, solvent free epoxy resin curing agent based on the new light colored breakthrough in phenalkamine technology.
Designed especially for 100% solids coatings has an excellent balance of cure speed and pot life, which enables coatings
to be applied with conventional spray equipment and provide an increased application window for the heavy duty protective
coatings industry.

Typical Uses: AquaGuard 5001 phenalkamines feature rapid cure and property development at ambient and low temperatures,
superior water resistance, and good adhesion to marginally prepared surface (including rusty, cold, wet or damp surfaces). Most
epoxy phenalkamine coatings show no blush even under cold and damp conditions.

APPLICATIONS: One or two coats depending on the porosity of the surface.
100% solids epoxy primers, direct to metal, concrete, masonary, mastics, and mid-coats
for marine (especially ballast tanks and edge retentive areas), industrial maintenance, tank,
pipe, and railcar applications. Coatings may be tinted.

ADVANTAGES:

• Excellent combination of rapid cure • All season cure
and long pot-life at both ambient • 100% Solids
and low (< 40°F) temperature • Non brittle
• Superior corrosion resistance • Good chemical resistance
• Outstanding adhesion to poorly
prepared surfaces


Weight, Ibs/gal…………………………………………………………………………9.5 +/-0.5
Theoretical Coverage, mil. sq. ft./gal....................................................................................1600
Recommended Coverage, mil. sq. ft./gal.................................................................................3-5
For steel surfaces…………………………………………………….....……………………..6-8
VOC Content (mixed), g/l.……………………………………………………………….....<100
Flash Point (mixed). °F……………………………………………………………………..>200
Mix Ratio, Ratio, parts A & B…………………………………………………………….....2:1
Pot life, minutes @ 77°F………………………………………………………………………35
Color……………………………………………………………………………………..AMBER


Coverage to Achieve Dry Film Thickness, sq.ft./gal
(actual-allows for approximate loss of 15%)
@ 3 mils..................................................................................................................................453
@ 5 mils..................................................................................................................................272
@ 8 mils..................................................................................................................................170


Drying Time @ 77°F and 50% relative humidity
To Touch.............................................................................................................................4 hours
To handle.............................................................................................................................6 hours
To topcoat........................................................................................................................8-12 hours


Note: Application of an immediate application of top coat shall be applied after AG 5001 has dried tack free or while it is
tacky or pliable. If re-coat time exceeds 1 week, the surface must be mechanically abraded and re-primed with AG 5001.
Do not allow AG 5001 to puddle.

Cure Time @ 77°F and 50% relative humidty.
To touch..........................................................................................................................4 hours
To handle.........................................................................................................................6 hours
To topcoat.................................................................................................................8 - 12 hours
*Force curing is required for low temperature applications to expedite curing process.